防爆安全温度计(美国),ThermoProbe,

,TP-5C升级版TP9,用起来更方便,更精准,美国直销,美国直接购买,价格特别优势

测温范围:-40 to +400°F
-40 to +204°C

误差:
±0.2°F from 32 to 200°F 
±0.5°F from 200 to 400°F
±0.1°C from 0 to 100°C 
±0.3°C from 100 to 200°C

2节AA碱性电池寿命约200小时
外壳材料:
不锈钢

探针
304不锈钢

尺寸:
10“×4.25”x 6.4“W

The TP9 employs the proven RTD design that has been used in the TP7 and TP8 for many years. A sealed industrial quality overlay provides a user interface that is easy to use with gloves. A stainless steel enclosure protects the circuit board and large LCD from penetration by impact water and reactive liquids.
The new TP9 circuit board is an evolutionary step up from our highly accurate reliable and successful TL1 laboratory thermometer. The Power Button’s primary function powers the instrument for intervals of about 20 minutes since the last button was accessed. The Power Button can also be used to conserve power and clear the memory or to make adjustment while in calibration mode. A simple menu operation is displayed by holding the Function Button and alternately functions to allow adjustments in the calibration mode. Arrows on the left side of the display show the direction of the temperature reading and whether stability has been reached. At the user’s discretion stabilized temperatures can be logged at numerous liquid levels for a running average and later displayed for the user’s documenting purposes. But this feature never interferes with simply getting an accurate temperature reading.
To endure the environment and be intrinsically safe the TP 9 is manufactured of materials which are both immune to petrochemicals and are non-sparking. The enclosure is made of stainless steel. The probe assembly is constructed using non-stick cable and stainless steel sensor components.

Specifications 
Maximum Dimensions:
10”L x 4.25”H x 6.4” W

Probe
304 Stainless Steel Sealant Aramid Fiber Reinforced FEP or PFA 
Cable Jacket Coaxial Construction

Enclosure Material:
Stainless Steel
Acetal (Delrin) Probe Holder
Polyvinylchloride Faceplate
Stainless Steel Fasteners
 

Batteries:
2 AA Alkaline; Battery Life of approximately 200 hours
Battery manufacturer’s battery operating temperatature range -4 to 130°F -20 to 54°C
Note: Battery may not provide adequate power if ambient temperature is extremely low or high.

Temperature:
Resolution 0.01
Range: -40 to +400°F
-40 to +204°C
Calibrated Accuracy:
±0.2°F from 32 to 200°F 
±0.5°F from 200 to 400°F
±0.1°C from 0 to 100°C 
±0.3°C from 100 to 200°C
4 Point NIST Traceable Report of Test
Long-term drift not to exceed 0.05%/year
Meets API requirements